China Waterworks Facility Monitoring

China Waterworks Facility Monitoring

Korenix China Waterworks Facility Monitoring , Changde city/Hunan

As the demand for improving water quality for reuse increases, the reliable operation of Waterworks facilities becomes of high importance. Monitoring the operation of the Waterworks systems in real-time is a challenge for companies since they work non-stop, requiring construction of advanced, highly reliable, redundant and automated network infrastructure systems.

The challenges here are numerous: communication of widely distributed equipment across the plants that occupy large areas, prevention from network electromagnetic interference and radio frequency interference, resistance to harsh environment conditions, etc. In Shanghai a Waterworks Facility chose to use Korenix Ethernet switches for its plant monitoring project. 

The JetNet 5210G switches distributed throughout the plants connected and extended data from PLCs to the control center by forming a redundant ring through the fiber ports. The supported MSR with its very fast recovery time allowed administrator to communicate the non-stop data with the JetNet 5428G rackmount switch in monitoring room over long distances. In addition to extending data between widely distributed plants, optical fiber cable also helped to resist the electromagnetic interference.


Korenix China Waterworks Facility Monitoring

Since the JetNet 5210G supports Modbus TCP, the network designer was able to integrate them in HMI systems deployed at different plants of the facility to further enhance monitoring, maintenance and network control of equipment, without the need of using additional monitoring tools.

The project, which initially used AC to DC24V power backup system to charge the battery (this obviously resulted a very poor power quality), also required a solution, that could ensure high quality of the power system. By choosing JetNet 5210G with a built-in dual 10~60VDC power input range, the network operator was able to improve the power quality and reliability in the Waterworks facility.
The rugged parameters of the switches that conformed with heavy industry EMS and EMI requirements, have been yet another key factor for users’ choice of the switches. By further offering the built-in watchdog timer, IP31 grade enclosure with -40~75oC wide operating temperature range, the JetNet 5210G was able to provide operation stability and reliability in the water plant exposed to intense electromagnetic interference, temperature changes, etc.


Why Korenix JetNet 5428G
  • EEE Energy saving
  • Friendly Device and Auto Network Topology utility
  • Isolated redundant power inputs with universal 24/48VDC power or 110/220 VAC power
  • Compliance with EN50121-4 and NEMA TS2
  • -40 to 75°C operating temperature, fanless

Why Korenix JetNet 5210G
  • Multiple event relay output for enhanced device alarm control
  • Hi-Pot Isolation Protection for ports and power
  • Railway Track Side EN50121-4 Certification
  • -40~75°C High Operating Temperature 
  • 10~36VDC Redundant wide range power input