| Technology |
|
|
IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3x Flow Control and Back-pressure IEEE 802.1p class of service IEEE 802.1Q VLAN | |
|
|
|
Store and Forward architecture | |
|
|
|
Broadcast packet filtering | |
| Interface |
|
|
| 5 x 10/100 Base-TX, Auto MDI/MDIX | |
|
|
|
10Base-T:2-pair UTP/STP Cat. 3, 4, 5 cable, EIA/TIA-568 100-ohm (100m) 100Base-TX:2-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m) | |
|
|
|
Per port: Link/Activity (Green), Full duplex/Collision (Green) Per unit: Power x 3 (Green), Fault (Red), R.M (Orange) | |
|
|
|
Relay output for port break and power failure | |
| Redundancy |
|
|
|
Super Ring with recovery time less than 300ms RSTP, STP | |
|
|
|
| Management |
|
|
| IGMP V1 & Query mode, DHCP / Client, TFTP, SNTP | |
|
|
|
Web-interface management Default button is provided to restore default settings. | |
|
|
|
Supports Port-based VLAN and IEEE802.1Q Tag VLAN | |
|
|
|
Four priority queues per port | |
|
|
|
Online traffic monitoring on selected ports | |
|
|
|
IP addresses are used to define access levels. | |
| Performance |
|
|
|
14,880 pps for Ethernet port and 148,800 pps for Fast Ethernet port | |
|
|
|
64 bytes to 1522 bytes (with VLAN tag) | |
|
|
|
|
|
|
|
|
|
| Power Requirements |
|
|
|
Input Voltage: 24 VDC (12 to 48 VDC), dual inputs Reverse Polarity Protection: Present | |
|
|
|
| Mechanical |
|
|
|
DIN-rail kit and wall-mounting ear | |
|
|
|
IP-31 protection, aluminum case | |
|
|
|
53 mm (W) x 135 mm (H) x 105mm (D) | |
| Environmental |
|
|
|
-10 to 70°C (14 to 158°F) | |
|
|
|
5% to 95% (Non-condensing) | |
|
|
|
-40 to 85°C (-40 to 185°F) | |
| Regulatory Approvals |
|
|
|
FCC Class A, EN55022 Class A | |
|
|
|
EN61000-4-2, EN61000-4-3, EN61000-4-4 EN61000-4-5, EN61000-4-6, EN61000-4-8, EN610004-11 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
305,482 hours * MIL-HDBK-217F GB (MILITARY HANDBOOK) standard | |
|
|
|