| Technology |
|
|
|
IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3x Flow Control and Back-pressure
| |
|
|
|
Store and Forward architecture | |
| Interface |
|
|
|
5 x 10/100 Base-TX, Auto MDI/MDIX | |
|
|
|
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable, EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5 cable, EIA/TIA-568 100-ohm (100m) | |
|
|
|
Per port: Link/Activity (Green), Full duplex/Collision (Green) Per unit: Power x 3 (Green) | |
| Performance |
|
|
|
14,880 pps for Ethernet port and 148,800 pps for Fast Ethernet port | |
|
|
|
64 bytes to 1522 bytes (with VLAN tag) | |
|
|
|
|
|
|
|
|
|
| Power Requirements |
|
|
|
Input Voltage: 24 VDC(12 to 48 VDC), dual inputs Reverse Polatiry Protection: Present | |
|
|
|
| Mechanical |
|
|
|
DIN-Rail kit and wall mounting ears | |
|
|
|
IP-30 protection, aluminum case | |
|
|
|
53 mm (W) x 135 mm (H) x 105mm (D) | |
| Environmental |
|
|
|
-10 to 70°C (14 to 158°F) | |
|
|
|
5% to 95% (Non-condensing) | |
|
|
|
-40 to 85°C (-40 to 185°F) | |
| Regulatory Approvals |
|
|
|
FCC Class A, EN55022 Class A | |
|
|
|
EN61000-4-2, EN61000-4-3, EN61000-4-4 EN6100-4-5, EN6100-4-6, EN6100-4-8, EN6100-4-11 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
448,564 (hours) * Calculated MTBF is based on MIL-HDBK-217F (MILITARY HANDBOOK) standard (This standardization handbook was developed by the US Department of Defense with the assistance of the military departments, federal agencies, and industry) | |
|
|
|
|
|
IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet IEEE 802.3x Flow Control and Back-pressure | |
|
|
|
|
|
| Store and forward switching architecture | |
|
|
14,880 pps for Ethernet port and 148,800 pps for Fast Ethernet port | |
|
|
|
|
|
|
|
|
|
|
|
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5 cable EIA/TIA-568 100-ohm (100m) | |
|
|
Per port: Link/Activity (Green), Full duplex/Collision (Green) Per unit: Power x 3 (Green) | |
|
|
|
|
|
|
|
|
12 to 48 VDC. Redundant power inputs with reverse polarity protection. A removable terminal block for master and slave power. | |
|
|
|
|
|
| DIN-Rail Kit, or wall mounting ears for 3-way installation | |
|
|
| -10°C to 70°C (14°F to 158°F) | |
|
|
| 5% to 95% (Non-condensing) | |
|
|
| -40°C to 85°C (-40°F to 185°F) | |
|
|
| IP-31, 53 mm (W) x 135 mm (H) x 105mm (D) | |
|
|
| FCC Class A, CE EN6100-4-2, CE EN6100-4-3, CE EN-6100-4-4, | |
|
|
CE EN6100-4-5, CE EN6100-4-4 UL, cUL, CE/EN60950 | |
|
|
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) | |
|
|
| 448,564 (hours) * MIL-HDBK-217F (MILITARY HANDBOOK) standard |
|
|
|